Produktinformationen
Service
|
Sterilisationsprodukt
|
|
Sterilisationsprodukte
Wir bieten eine umfangreiche Auswahl an Produkten zur Sterilisationskontrolle für den professionellen Gebrauch im Gesundheitswesen.
|
Das 3M™ Elektronisches Test-System (ETS) stellt den weltweit ersten und entscheidenden Schritt zur präzisen Sterilisationskontrolle dar.
|
|
Der 3M™ Data Logger liefert Softwaregesteuerte Zeit- und Temperaturdaten hoher Qualität, die die Leistung Ihres Reinigungs- und Desinfektionsgerätes optimieren.
|
Weitere Informationen zu den 3M Sterilisationsprodukten »
Exposure 3M Exposure Control products help to distinguish between processed and unprocessed medical devices at a glance. They assure the sterilizer operator that each pack or item has been exposed to the sterilization process, without the need to open the pack.
|
3M™ Comply™ Dry-Heat Indicator Tape
This chemical indicator tape is designed for use as packaging tape and for the immediate identification of items exposed to dry heat processing.
|
|
3M™ Comply™ Ethylene Oxide Indicator Tape
A reliable indicator tape designed to facilitate the immediate identification of items exposed to an EO sterilization process, and for packaging purposes.
|
|
3M™ Comply™ Indicator Labels
These simple, convenient labels allow easy verification that products have been processed. The pressure sensitive adhesive allows easy removal after processing. Especially suitable for hard surface items.
|
|
3M™ Comply™ Instrument Protector
Designed to protect sharp-pointed instruments from damage and reduce the possibility of pouch puncture during sterilization. Indicators on the protectors verify steam or EO gas processing.
|
|
3M™ Comply™ Steam Indicator Tapes
The chemical indicators of choice for steam autoclaves for over 25 years.
|
|
3M™ Scotch® High Temperature Masking Tape
A high performance, smooth crepe masking tape with good adhesion and tack properties for porous load steam sterilization processes.
|
|
Indicator Tape Dispenser and Blade
For use with all tapes in our range.
|
Load Load Control is the process by which a load is monitored and released based on the result of a biological or chemical indicator in a test pack or process challenge device. 3M has a full line of steam and EO biological indicators with results in as little as one hour, and chemical indicators of class 4, 5 and 6, providing instantaneous, unambiguous results.
|
3M Attest Biological Monitoring Indicators and Present Incubators
True biological indicators which are easy to use and give a clear colour change results within 24 to 48 hours of processing.
|
|
3M Attest Rapid Readout Biological Monitoring System
The 3M Attest Rapid Readout Biological Monitoring System consists of true biological indicators, that provide clear, easy to interpret biological results in just 1 - 4 hours.
|
Pack Pack control involves the use of chemical indicators for internal monitoring of packs, trays, containers and peel pouches. The appropriate product from 3M’s wide range of chemical indicators is placed inside each pack and immediately identifies whether the conditions for sterilization have been met.
|
3M Comply Colour Change Chemical Indicators
Reliable, multi-variable indicator strips that offer an accurate and consistent low-cost method of monitoring the sterilization process.
|
|
3M Comply Moving Front Chemical Integrators
Obtain unambiguous and easy to interpret results with these dual method indicators.
|
|
3M Comply Sequential Response Chemical Indicators
Sequential response multi-variable indicator strips react sequentially to the parameters of sterilization, such as time, steam and temperature. They also provide some indication of sterilant quality.
|
 |
3M Comply (SteriGage) Steam and EO Chemical Indicators
Designed to monitor exposure to steam or EO conditions in a pack. Provides a visual accept/reject readout to determine that the sterilant has penetrated to the point of placement in the pack and confirm that sufficient exposure conditions occurred.
|
Protein Testing
The 3M™ Clean-Trace™ Protein Test is simple and effective to use, detecting whether protein has been left behind on surfaces after inadequate cleaning. It indicates whether a medical device has been cleaned to the standard required by HTM 2030 and BS EN ISO 15883.
The Clean-Trace test is very easy to use:
- Add four drops of moisturiser to the swab (avoiding protein contamination from the operator)
- Swab the re-usable medical device
- Insert the swab back into the tube and push down to activate the test. Shake rapidly from side to side for at least 5 seconds.
- Incubate for 20 minutes at 45°C
- After incubation time is complete, compare the colour of the test to the colour chart on the device label.
If it’s green, it’s clean If it’s purple, protein is present.
Free demonstration of the Clean-Trace protein test
Please complete and submit the form below and your representative will call you to arrange a demonstration of the Clean- Trace protein test.